| Axial Flow Fans |
| |
- AL
- AL(N)
- dAL
- dAL(N)
- ESN
- dESN
- ES
- EST
- GAL
- dGAL
- DV
- KGL
| |
| Axial Flow Fans - Type AL |
| |
| Axial flow fans of type AL with excellent aerodynamical characteristics. The exact profile of the rotating blades ensures high efficiency. |
| |
| Type Of Construction |
 |
| Axial impeller with guiding device, profiled rotating blades, steel housing, mounting claws, impeller of Silumin. |
| Application |
| Industry, tunnel and gallery ventilation, without requirement of explosion- or flame-proofness, with big volume. |
| Power |
| Volume flow up to 100 m3/s, overall pressure up to 3000 Pa. |
| Control |
| Pole-changing motors, infinitely variable speed, individually adjustable blades. |
| Drive |
| Three-phase squirrel-cage motor, special design, type of protection IP 55, isolation class F, tropic-proof, terminal box inside or outside. |
| Paint Coat |
| Pure white (RAL 9010). |
|
| |
| Axial Flow Fans - Type AL(N) |
| |
| Low-pressure fans of type AL(N) with excellent aerodynamical characteristics. The exact profile of the rotating blades ensures high efficiency. |
| |
| Type Of Construction |
 |
| Axial impeller with guiding device, profiled rotating blades, steel housing, footing, impeller of Silumin. |
| Application |
| Industry, tunnel and gallery ventilation, where explosion- or flame-proofness is not required. Flexible use of the fan at construction sites, e.g. refurbishment of tunnels. As open-jet fan or for short pipelines. |
| Power |
| Volume flow up to 16 m3/s, overall pressure up to 1100 Pa. |
| Control |
| Pole-changing motors, infinitely variable speed, individually adjustable blades |
| Drive |
| Three-phase squirrel-cage motor, special design, type of protection IP 55, isolation class F, tropic-proof, outside safety switch. |
| Paint Coat |
| Pure white (RAL 9010). |
|
| |
| Axial Flow Fans - Type dAL |
| |
| Axial flow fans of type dAL with excellent aerodynamical characteristics. The exact profile of the rotating blades ensures high efficiency. Drive motor totally enclosed, explosion and flame-proof. |
| |
| Type Of Construction |
 |
| Axial impeller with guiding device, profiled rotating blades, flame-proof, steel housing, mounting claws, impeller of Silumin, ring of Silumin or brass. |
| Application |
| Industry, tunnel and gallery ventilation as well as mining ventilation where flame-proofness is required, with big volume. |
| Power |
| Volume flow up to 100 m3/s, overall pressure up to 3000 Pa. |
| Control |
| Pole-changing motors, infinitely variable speed, individually adjustable blades. |
| Drive |
| Three-phase squirrel-cage motor, special design, explosion-proof, pressure-proof housing “d” or “de” acc. to DIN EN 50018, terminal box inside or outside. |
| Paint Coat |
| Pure white (RAL 9010). |
|
| |
| Axial Flow Fans - Type dAL(N) |
| |
| Axial flow fans of type dAL(N) with excellent aerodynamical characteristics. The exact profile of the rotating blades ensures high efficiency. Drive motor totally enclosed, explosion- and flame-proof. |
| |
| Type Of Construction |
 |
| Axial impeller with guiding device, profiled rotating blades, flame-proof, steel housing, footing, impeller of Silumin, ring of Silumin or brass. |
| Application |
| Industry, tunnel and gallery ventilation as well as mining ventilation where flame-proofness is required. Flexible use of the fan at construction sites, e.g. refurbishment of tunnels for methane drainage. |
| Power |
| Volume flow up to 16 m3/s, overall pressure up to 1100 Pa. |
| Control |
| Pole-changing motors, infinitely variable speed, individually adjustable blades. |
| Drive |
| Three-phase squirrel-cage motor, special design, explosion-proof, pressure-proof housing “d” or “de” acc. to DIN EN 50018, terminal box inside or outside. |
| Paint Coat |
| Pure white (RAL 9010). |
|
| |
| Axial Flow Fans - Type ESN |
| |
| Axial flow fans of type ESN with excellent aerodynamical characteristics. The exact profile of the rotating blades ensures high pressure rates and efficiency. |
| |
| Type Of Construction |
 |
| Axial impeller with guiding device, profiled rotating blades, steel housing, impeller of Silumin. |
| Application |
| Tunnel and gallery ventilations in areas where nobody has to expect the occurrence of flammable atmosphere caused by gas. |
| Power |
| Volume flow up to 20 m3/s, overall pressure up to 3500 Pa. |
| Control |
| Pole-changing motors, infinitely variable speed, individually adjustable blades. |
| Drive |
| Three-phase squirrel-cage motors, special design, protection type IP 55, isolation class F, tropic-proof, terminal box outside. |
| Paint Coat |
| Pure white (RAL 9010). |
|
| |
| Axial Flow Fans - Type dESN |
| |
| Axial flow fans of type dESN with excellent aerodynamical characteristics. The exact profile of the rotating blades ensures high pressure rates and efficiency. |
| |
| Type Of Construction |
 |
| Axial impeller with guiding device, profiled rotating blades, steel housing, explosion-proof, impeller and ring of Silumin. |
| Application |
| Industry, tunnel and gallery ventilations, in potentially explosive surroundings. |
| Power |
| Volume flow up to 20 m3/s, overall pressure up to 3500 Pa. |
| Control |
| Pole-changing motors, infinitely variable speed, individually adjustable blades. |
| Drive |
| Three-phase squirrel-cage motor, special design, explosion-proof, pressure-proof housing “d” or “de” acc. to DIN EN 50018, terminal box outside. |
| Paint Coat |
| Pure white (RAL 9010). |
|
| |
| Axial Flow Fans - Type ES |
| |
| Axial flow fans of type ES with excellent aerodynamical characteristics. The exact profile of the rotating blades ensures high pressure rates and efficiency. |
| |
| Type Of Construction |
 |
| Axial impeller with guiding device, profiled rotating blades, steel housing, explosion-proof, impeller and ring of Silumin. |
| Application |
| Mining, in explosive surroundings. |
| Power |
| Volume flow up to 20 m3/s, overall pressure up to 3500 Pa. |
| Control |
| Pole-changing motors, infinitely variable speed, individually adjustable blades. |
| Drive |
| Three-phase squirrel-cage motor, special design, explosion-proof, pressure-proof housing “d” or “de” acc. to DIN EN 50018, terminal box inside or outside. |
| Paint Coat |
| Pure white (RAL 9010). |
|
| |
| Axial Flow Fans - Type EST |
| |
| EST fans combine the advantages of electric and compressed-air drive. The compressed-air drive is preferably used in case of emergency, e.g. power failure or if limiting values of explosive gas mixtures are exceeded suddenly. |
| |
| Type Of Construction |
 |
| Axial impeller with guiding device, profiled rotating blades, flame-proof, inlet and exhaust housing of Silumin. |
| Application |
| Tunnel and gallery ventilations, in explosive surroundings as well as compressed-air drive in case of increased occurrence of methane gas. Drive in combination. |
| Power |
| Volume flow up to 17 m3/s, overall pressure up to 3000 Pa. |
| Control |
| Pole-changing motors, infinitely variable speed. Continuously variable by regulating the air pressure and the number of driving nozzles. |
| Drive |
| Three-phase squirrel-cage motor, special design, explosion-proof, pressure-proof housing “d” acc. to DIN EN 50018, terminal box inside or outside. |
| Paint Coat |
| Pure white (RAL 9010). |
|
| |
| Axial Flow Fans - Type GAL |
| |
| Contra rotating high-pressure fans provide high pressures at efficiency rates of up to more than 90% in both gratings because of interesting flow processes. Simple construction without guiding wheel, including two drive motors. |
| |
| Type Of Construction |
 |
| Two contra rotating axial impellers, profiled rotating blades, steel housing, mounting claws, impeller of Silumin. |
| Application |
| Industry, tunnel and gallery ventilation, where flame- or explosion-proofness is not required, but working under high pressures. |
| Power |
| Volume flow up to 45 m3/s, overall pressure up to 6000 Pa. |
| Control |
| Pole-changing motors, infinitely variable speed, individually adjustable blades. |
| Drive |
| Three-phase squirrel-cage motor, special design, type of protection IP 55, isolation class F, tropic-proof, terminal box inside or outside. |
| Paint Coat |
| Pure white (RAL 9010). |
|
| |
| Axial Flow Fans - Type dGAL |
| |
| Contra rotating high-pressure fans provide high pressures at efficiency rates of up to more than 90 % in both gratings because of interesting flow processes. Simple construction without guiding wheel, including two drive motors. |
| |
| Type Of Construction |
 |
| Two contra rotating axial impellers, profiled rotating blades, steel housing, impeller of Silumin, ring of Silumin or brass. |
| Application |
| Industry, tunnel and gallery ventilation as well as mining ventilation where flame-proofness is required, as well as working under high pressures. |
| Power |
| Volume flow up to 45 m3/s, overall pressure up to 6000 Pa. |
| Control |
| Pole-changing motors, infinitely variable speed, individually adjustable blades. |
| Drive |
| Three-phase squirrel-cage motor, special design, explosion-proof, pressure-proof housing “d” or “de” acc. to DIN EN 50018, terminal box inside or outside. |
| Paint Coat |
| Pure white (RAL 9010). |
|
| |
| Axial Flow Fans - Type DV |
| |
| Turbine fan with compressed air as kind of drive. Impeller and impulse turbine of high-quality Silumin form a whole. By changing the volume of compressed-air, the power is continuously adjustable. Turbine fans are preferably used in mining and potentially explosive areas. |
| |
| Type Of Construction |
 |
| Axial impeller with guiding device, profiled rotating blades, flame-proof, inlet and exhaust housing of Silumin, turbine ring of brass or steel. |
| Application |
| Ventilations, where flame-proofness is required at compressed-air supply. |
| Power |
| Volume flow up to 15 m3/s, overall pressure up to 2000 Pa. |
| Control |
| Continuous control of the drive pressure. |
| Drive |
| Impulse turbine at the impeller circumference, operating pressure 4-6 bar. |
| Paint Coat |
| Pure white (RAL 9010). |
|
| |
| Axial Flow Fans - Type KGL |
| |
| Large fan for large yields of mines. Drive by means of cardan shaft outside of the motor. Power regulation by speed adjustment and/or adjustable blades. |
| |
| Type Of Construction |
 |
| Axial impeller with guiding device, profiled rotating blades, steel housing, footing, motor arranged outside, drive by means of cardan shaft. |
| Application |
| Big fan used in big caverns and mines. |
| Power |
| Volume flow up to 180 m3/s, overall pressure up to 4000 Pa. |
| Control |
| Pole-changing, infinitely variable speed. |
| Drive |
| Three-phase squirrel-cage motor, special design depending on the location and area. |
| Paint Coat |
| Pure white (RAL 9010). |
|
|
|